This note uses the formulation described in the note Transit Time Equivalent Circuit for a Superconducting RF Cavity, ESS Docs Document 294-v1 to calculate the loaded quality factor for spoke cavities and the medium beta cavities of the ESS linac. The lattice data is from the OPTIMUS lattice released on 26-July-2013. The beam current assumed is 62.5 mA.